In the event of a fire, the greatest danger to human life is not fire and high air temperature, but smoke. It could trigger a panic, disorient people and cause poisoning. In order to prevent such problems, the premises are installed in smoke removal, which can localize carbon monoxide, clean the room from small particles of dust and ash.
The smoke removal system is an emergency complex of supply and exhaust ventilation, creating the conditions for the evacuation of people in a fire. The missile defense system is included in the overall fire safety set.
When fire alarm is triggered, fire ventilation is turned on. The system begins to actively remove combustion products and smoke from the focus of the fire, as well as prevent their distribution to other zones of the room. Lighting fans direct clean air to fire and main outputs, to staircases and elevators.
In accordance with the construction standards, such installations should be equipped with high-rise buildings (more than 10 floors) with a fire safety class, rooms without natural ventilation, underground structures, prisons, hospitals and other institutions in which a large number of people are focused.
The smoke removal system performs the following tasks:
The fire -fighting ventilation system functions according to the laws of physics: cold air drops down the room, and the warm air rises up. Equipment for the removal of warm air will restrain the increase in temperature and reduce the negative effect of smoke on the human body.
The smoke removal system is an expensive complex, its technical characteristics and the appropriate structure require special design.
To date, all smoke removal systems can be divided into static and dynamic complexes.
At static smoke removal There is an emergency shutdown of ventilation. At the same time, smoke does not go to other zones of the room. Such a system is most primitive and affordable. In fact, smoke removal, as such, does not occur, all smoke is localized in one room.
Dynamic system Designed for the removal of smoke and burning, as well as for the influx of fresh air. The work of the complex is based on the use of fans that pull the combustion products outside the room.
Dynamic complexes can function on one fan that works alternately in different directions (suction of smoke or supplies of fresh air), on separate fans of supply and confusion, or on combinations of two axial fans.
The choice of smoke removal scheme depends on the features of the construction of the building and the possibility of implementing a particular project.
According to the type of control, the Soda is divided into automatic and semi -automatic systems.
Automatic smoke removal is associated with the security system of the object, the installation of automatic fire extinguishing and fire alarm.
Buildings equipped with a large number of equipment and engineering systems are desirable to equip an automatic smoke removal system. The complex fire extinguishing and smoke removal system practically eliminates the risk of fire and spread of fire, giving a signal about the slightest breakdown of equipment
Smokewood is carried out through existing ventilation shafts, the inner surface of which is covered with a fire retardant. However, the use of individual communications with special fans and air ducts is considered more effective.
The dynamic smoke removal system consists of the following main elements:
Fans of smoke removal Large heat -resistant installations of high power. Minimum air flow 20,000 m3/h. Fasters of smoke removal are capable of working at very high temperatures.
The fan pumps smoke, combustion products from the place of fire. Some models of fans perform two functions alternately: the supply of clean air and the removal of smoke. Smokers fans are mounted on the roof of the building.
Air support fans Create excess pressure on the stairwells, in elevator shafts and vestibules of gateways, excluding their smoke.
No less important element of the smoke removal system fire valves. Four categories of fire valves are distinguished:
Lukes of smoke removal They are mounted on the roofs of buildings and when a fire occurs automatically open. As such hatches, anti -aircraft lights can be used, which under normal conditions perform the functions of lighting and ventilation.
Ventilation channels of smoke removal (mines) large cross -section ducts made of black steel. The thickness of the material should be at least 1.2 mm, this increases the stability of the ducts of the smoke removal to high temperatures.
The automatic complexes provide smoke sensors that work when the focus of the fire appears, and the signal for inclusion in the operation of fans and fire valves.
Let us consider in a stages the working cycle of a smoke removal system:
Important! The smoke removal system is designed to pump smoke from one fire of the fire. That is, all smoke is removed from one grate of the system (conditionally one, since each zone may account for several gratings). On the remaining floors and zones of the room, fire valves of the systems will be closed
The requirements for the design and maintenance of smoke removal systems are quite high, so engineers designers should be done by this work. The company's specialists will calculate smoke removal, prepare a working project, carry out installation and commissioning of equipment, and also conduct tests of the system.
When calculating and developing a smoke removal scheme, the following room parameters are taken into account:
All factors that can affect the rate of distribution and the amount of smoke during the fire are taken into account
The smoke removal project is drawn up on the basis of building codes and rules, where the minimum requirements for the fire ventilation system are clearly spelled out. The main document regulating the design procedure is the calculated determination of the main parameters of antidium ventilation of buildings from 2008.
Normative documents determine the capabilities of the smoke removal system:
The company performing the development and installation of a smoke removal system must have a license of the Russian Emergencies Ministry for the installation, maintenance and repair of fire safety equipment
When developing a project and installing a smoke removal system, experts recommend taking into account a number of fundamentally important points:
The arrangement of fireproof partitions has a significant impact on the wiring of the ducts. Changes in the place of placement of such a partition can lead to a reorganization of air wiring. This is especially true if each room uses a separate supply installation.
The development of a smoke exhaust project and the installation of the system will cost approximately 2000 rubles/m2. The price will depend on the complexity of the project and the equipment used.
The smoke removal system costs 2-3 times more expensive than a conventional ventilation system
The calculation of the cost is based on the following components:
The initial stage of installation is the laying of welded ducts in the room according to the developed plan. After that, they start installing fans. Axial, radial or roof fans can be used.
An important stage in the installation of smoke removal processing of mines with a special coating that protects the complex from fire. After the necessary level of fire resistance on the air ducts is reached, the installation of fire valves is installed, they are placed in mines passing under the ceiling.
The mounting of the air ducts and the placement of valves is performed with clear compliance with the requirements of the working documentation
The final stage connection of automation, adjustment and testing of the smoke removal system.
When adjusting the system, it is necessary to check the operation of the valves in manual and automatic mode, perform the calculation of the actual air flow (preferably separately for each zone), check the fan speed.
During the commissioning, it is necessary to give the fans a vacation at least one hour every 30 minutes
When checking the operation of retaining fans, you need to pay attention to the following parameters:
Using the measuring device of the dipmanometer, it is necessary to determine the excess pressure in the shafts of the elevators, stairwells and vestibules-blues.
The pressure difference between the street and the room should be at least 20 per this means that the fan's support meets the established standards, and the smoke removal system is calculated correctly
For each smoke removal system, the maintenance schedule is developed. Instructions for planned maintenance are provided by the company manufacturer and installer of the system.
Timely maintenance eliminates the likelihood of failure of fire ventilation at the most crucial moment. During the system check, it is possible to identify problems in time and eliminate them, replace some elements of the complex with more modern equipment.
Maintenance is carried out monthly and quarterly. Once a month they perform such work:
The quarterly check includes the following measures:
The results of each audit should be recorded in the journal of the established form.
It is safe to say that the smoke removal system is vital to ensure the safety of people during a fire. The development and equipment of the system is determined at the design stage, the equipment should be certified, and the control and maintenance of the complex comply with the established norms of the Russian Federation.