Cosiness and comfort of a country house depend not only on reliable walls and roofs, but also on ...
Cosiness and comfort of a country house depend not only on reliable walls and roofs, but also on ... |
Glass designs over the past few years have gained just very popularity ... |
Quite often, during the repair, there is a need to dismantle the old floor ... |
In connection with the climatic features of the terrain, many owners of private houses, whether it is buildings with individual roofs of complex configuration or with simple gable structures, more than once faced the problem of accumulating large masses of snow on them, which, with the onset of intersuzon, led to inexted consequences. Among the most common of them are the destruction of roof materials, frozen water in drain pipes and, as a result, impaired drainage, as well as mass melting of snow rushing a stormy stream into drainage systems, which cannot cope with the uncontrolled stream of water and dirt. Water formed as a result of melting an avalanche -like snow from the roofs of snow rushes into the gutter, where it intensifies the layer by the layer. In addition, the gutters are affected by uneven loads that they experience as a result of the intention of icicles. All this will ultimately disable the drainage system. To eliminate these unpleasant consequences, it is necessary to constantly cleanse the surface of accumulated snow and timely knock icicles in a timely manner, which also create a traumatic situation for people. In order to radically solve the problem, having simplified the care of the storm drain system as much as possible, experts propose to install an anti -icing system based on a heating cable, which can be laid as an independent element along the edge of the roof to prevent its icing. How to understand the characteristics of heating cables and how to correctly install a snowmeling system and anti -disclosure. We will consider further.
After the air temperature reaches negative values, crystallization of water begins, which helps to reduce the operational qualities of elements of the drainage system. How does this happen?
To prevent all of the above negative consequences, in the most unfavorable places of the roof (drain pipes, gutters, lends), heating cables that prevent the formation of ice in the course of meltwater movement are installed. Cable power is carried out from an electric network with a voltage of 220-230 V.
The heating process is controlled through a special thermostat that works automatically. Teams to the thermostat come from the sensors installed on the roof. In the event of situations that can cause ice formation, for example, precipitation in a cold period of time or a thaw with dripping snow, the thermostat gives a signal about the need to supply energy, as a result of which the heating of the electric cable begins. This leads to the formation of water, freely flowing through pipes and gutters. Today, programmable thermostats were replaced by the thermostats.
Important! Experts do not recommend reducing the cost of work and mount the heating cable only on the surface of the roof, refusing to heat the gutters. This is due to the fact that snow and ice can often clog the gutters and drainage pipes, which can lead to a violation of their integrity. To prevent this from happening, it is necessary to ensure unhindered convergence of melt water from the roof.
Important! If you refuse the installation of a heating system of drains and roofs, motivating it with high costs for electricity, experts are in a hurry to dispel your doubts provided that the cable is laying, the latter will provide reliable heating of the storm gutters, while consuming no more than 200-500 watts, which depends on Roof areas.
Heating part includes:
Distribution and information part is a kit that includes:
This part of the system is responsible for the transmission of electric power to the heating part, as well as the transmission of signals from the sensors of control of the roof heating to the control panel.
Control system, which includes the following elements:
Important! In general, the equipment of the control subsystem is selected taking into account the power of the system of anti -delaying drains and roofs. The heating part, for the installation of which a self -regulating cable was used, can operate automatic control. This is due to its ability to independently regulate power under the influence of temperature and the presence of precipitation.
The design features and the principle of installation of the heating system of drains and roofs depend on the following factors:
Particular attention must be paid to the varieties of the roof, which directly determines the design features of the system of anti -icing of drains.
Roof heating zones Places of the greatest accumulation of snow and ice, where it is necessary to lay an electric cable. To ensure unhindered drainage of melt water, cable laying is carried out in the following areas:
Important! Planning heating of drains should be carried out taking into account the heating of the entire roof, since otherwise the effectiveness of the entire system is reduced.
Important! During the installation of the system, the anti -icing cable is laid in the course of the drainage of melt water. It is important to use only waterproof sections, and their fixation is carried out as reliably as possible. Often, cable tension limiters are installed on top of the drain pipes.
The operation of an electric cable used to heat the gutters and roofs is carried out in technically difficult conditions, moisture, temperature changes, and mechanical loads are affected. In this regard, he must meet the following requirements:
Important!You can purchase an electric cable in the bays or in the form of ready -made sections, which are fragments of a fixed length cable with a coupling and a wire designed to connect to the network.
The cable supplied in bays is most often used for water -resistant and installation of anti -icing systems on roofs of complex configuration, and therefore, in standard situations, experienced craftsmen advise choosing ready -made sections. They are considered a more convenient option, easy to install.
The functioning of anti -icing systems can be carried out on the basis of warming cables of two types:
Let us consider in more detail the characteristics of each group.
Type No. 1. Reset cables
Resistant cables The traditional option, a distinctive feature of which is the same output power along the entire length and the same heat generation. The section is a metal core, an insulating layer, a copper braid and an outer shell. During the installation of anti-icing systems, it is recommended to use resistive cables, the heat emission of which is 15-30 W/m, and the operating temperature is 250 degrees.
Important! One of the main features of the resistive cable is constant resistance and the same heating along the entire length. The degree of heating is determined only by the current strength and does not depend on the external conditions that can be diametrically opposite to different sections of the cable. For example, one of the sections of the cable can be located in a pipe, the other in the open air, and the third is hidden under foliage or snow. In this regard, the optimal functioning of a particular section of the cable requires a different amount of heat, but the resistive cable cannot independently regulate the temperature depending on external conditions. This is the cause of high, but often unproductive energy consumption.
Several varieties of resistive cables are distinguished:
Consistent resistive cables are a variety that is characterized by a fairly simple structure. Its basis is a continuous conductive vein, represented by a copper wire and covered with an insulating layer on top. On top, the wire is covered with a shielding braid that prevents electromagnetic radiation and performs grounding function. The outer layer of the wire is represented by a polymer shell that protects from a short circuit.
Advantages of a consistent resistive cable:
Zonal resistive cables An advanced variety of consecutive cables, the constructive basis of which is two parallelly located veins that conduct current. Around them, a heating wire, screwed in the form of a spiral and characterized by high resistance. Usually nichrome, this spiral through the contact windows in isolation alternately interacts with both conductive cores, forming independent heat generation zones. In case of overheating, only one functional zone will fail, while the rest will continue their work.
Advantages of a resistive zonal cable:
Type No. 2. Self -regulatory cables
Self -regulating cablesThey differ from their resistive analogue by the presence of a matrix of a semiconductor layer connecting two conductive veins. In addition, on the cut of a self -regulating cable, you can see a photopolymer isolation, an shielding shell represented by a foil or a wire braid, as well as external plastic insulation.
Important! Due to the presence of two insulating layers (internal and external), the self -regulating cable acquires high dielectric strength and resistance to shock loads.
Important! The matrix is \u200b\u200bthe main distinguishing detail of self -regulating cables. It changes its resistance depending on the ambient temperature. For example, with an increase in the temperature of atmospheric air, the resistance of the matrix increases, which helps to reduce the heating of the cable itself. This is the principle of self -regulation, which underlies the work of a self -regulating cable.
Advantages of a self -regulating cable:
As devices used as a control system, the following can be noted:
The placement of connecting boxes should be carried out in such a way that free access to them is maintained. Usually they are mounted on a roof near heating elements. Installation under the visor, in the attic and parapets is also possible.
Before proceeding with the installation of the cable, it is necessary to calculate its length and determine the location. Since the sections on which the heating elements are laid, we examined above, we denote how to determine the length of the cable.
To do this, it is necessary to measure the length of all parts of the system, taking into account the quantity and cutting of the drain, as well as the length of the apple. For every 100-150 mm of the gutter, a power of 30-60 W/m is required.
When calculating the power of the electric cable, it is necessary to rely on regulatory indicators. If the resistive type for cables, the required power is 18-22 W/m, then for a self-regulating 15-30 W/m. It is important to remember if polymeric materials were used for the manufacture of the drainage system, the cable power should not exceed 17 W/m, which will avoid damage to the drainage system.
In the process of installing the heating system, it is necessary to prepare the following elements:
What to pay special attention to?
Many save on heating
Many save on heating of the roof and drains, but this can turn into corruption of the roof and the drainage system. I don’t want to take risks, therefore, immediately, when building a house, I installed a cable electric heating system Freezstop http: //strport.ru/stroitelstvo-domov/obogGrev-vodostokov-i-krovli-sistemy .... Over the past winter, the system showed itself well, Therefore, I can safely recommend it.